Pro-160 / 360 Fault Codes

The Pro-160 and Pro-360 have a number of warning messages or error codes that can appear depending on what the controller thinks is happening.

This table lists;

  • the code
  • any associated sound signal
  • whether the code is a warning or indicates a fault
  • the text shown on the display
  • the behaviour of the controller
Code Sound

[No of beeps in 5 secs]

Type

Fault/

Warning

Error Text

 

Error Description  Behaviour
B1 2 short W Under Voltage The battery voltage has gone below the Low Voltage cut-off (if set) or 11V (system default). Start-up – Do not start

Run-time – Ramp down

B2 2 short W Low Battery The battery voltage has gone below the low voltage alert (if set) or 11.9 (system default). Depends on profile setting (volt_alert.action)
B3 None W High Battery The battery voltage is above:

60V (Std PRO-160)

90V (HV PRO-160)

Flash warning message
B4 None F Over Voltage The battery voltage is above:

63V (Std PRO-160)

95V (HV PRO-160)

Start-up – Do not start

Run-time – Ramp down, resume if cleared

L1 None W Logging Error An error has occurred when writing to the uSD card Controller continues to run, but logging is disabled.
T1 1 long W High Temp The controller temperature is over 65C Flash warning message

Run-time – ramp down to 50% of max speed (if over 50%)

T2 1 long F Over Temp The controller temperature is over 75C Start-up – Do not start

Run-time – Ramp down, stop

T3 1long W TX High Temp The second thermistor temperature is over the warning limit. Flash warning message

 

T4 1 long W TY High Temp The third thermistor temperature is over the warning limit. Flash warning message

 

P1 Continuous F High Pot Lock High pot lockout.

Indicates the throttle input was not at zero when switched on. Either close the throttle, or increase the lockout setting in the menu.

Start -up -Flash error message until POT is set to minimum

Run-time -N/A

P2 3 short F Pot Fault Pot track fault.

Indicates a pot or pot wiring fault. Not usually a controller issue, but see note 1 at end.

Start-up – Flash error message and switch off

Run-time – Ramp down, stop

P3 3 short F Pot Fault

Pot wiper fault.

The POT input value is higher than the expected range. Usually indicates a worn pot or faulty pot wiring.

We recommend; 1] make sure software is 2.4.1 or later. 2]replace the pot.

Start-up – Flash error message and switch off

Run-time –

2.4.0 & earlier, ramp down & stop.

2.4.1 onwards, ramp down, resume if fault clears.

P4 3 short F RC Fault The RC signal is not in the expected range of values

See note 2 at end.

Start-up – Flash error message until signal is in range.

Run-time – Ramp down

Restart automatically if ranges return to normal

P5 3 short F Limit switch Both limit switches are being operated at the same time Start-up – Flash error message until at least one switch is opened.

Run time  – ramp down.

P6 3 short F Volt input If Vmode chk is enabled, this indicates an input below 0.25V or above 4.75V. Usually caused by a disconnection of the input, or a malfunction of the voltage source. Start-up – Do not start

Run-time – Ramp down, stop

X1 2 short F Dead Mans Hdl The Dead Man’s handle is set on Start-up – Flash error message until set off

Run-time  – Ramp down

Restart automatically if DMH goes off

X2 2 short F Emerg Stop Emergency stop signal received Start-up – Flash error message until set off

Run-time  – STOP IMMEDIATELY

C1 None W Over Current Current overload occurring. The current is above the SYSTEM (hardcoded) maximum safe curent.

[Note: whether it is + or – overcurrent is not information required by the user]

Flash warning message. Special behaviour, emergency stop after 300 milliseconds at this level.
C2 None W Current Limit Current limit. Current is being held to the current limit set for the profile Flash warning message.
K1 2 long F Park Brake Parking brake over current Start-up – Do not start

Run-time – Ramp down, stop

Q1-4 3 long F MOSFET Mosfet Faults. See note 3 at end. Start up check
S1 None W Speed Limit Speed limit. Speed (width of signal from speed sensor) is being held to the speed limit set for the profile Flash warning message.
S2 None W Speed Signal Reading from the speed sensor is not in the expected range of values Flash warning message

 

Notes:

1. P2 Pot fault can also occur if R111 [0 ohms] is blown. This can occur if pin F is accidentally short-circuited to B+. Test for continuity between the * point and pin F. If open circuit, it can be repaired by bridging with a small wire link. In July 2026, on Rev 7 of the control board, R111 was changed to be another fuse track [F2], this makes it easier to test and repair.

2. P4 RC fault can occur if the J1 jumper is missing [just above the RDO port on the control board]. Does not apply to Rev 7 hardware onwards [30-41-07].

3. Qx faults can also be caused by;

  • A short circuit between mosfets and the heatsink. Use a multi-meter set to the 200k resistance scale and measure between the heatsink and each of the B+/B-/M+/M- terminals in turn, there should be no discernible continuity. If there is then check that all the black insulating washers are in place on the mosfet mounting screws.
  • We have also seen two cases of false positive Q errors that were traced to faulty battery isolator switches which had developed a slightly high resistance across the internal contacts. This was identified by temporarily bypassing the isolator.
  • If a radio control receiver or servo is connected that draws too much current, this will affect the 5V supply to the microprocessor, which in turn can give a false positive Q error.