Knowledgebase Contact Us
How Can We Help?
< Knowledgebase
Print

Pro-100 Fault Codes

The Pro-100 has a number of warning messages or fault codes that can occur depending on what the controller thinks is happening. Each message has an associated sequence of warning beeps.

This table lists;

  • The code.
  • Any associated sound signal.
  • Whether the code is a warning or indicates a fault.
  • The text shown on the display [if fitted].
  • The behaviour of the controller.
Code Sound [every 5 secs] F/W Text shown Description
B1 1 short F Under Voltage Start-up – Do not start. Run-time – Ramp down, stop
B2 2 short W Low Battery Run-time – ramp down to 50% of max speed. Voltage must exceed low battery voltage (plus 1%) for 10 seconds to come out of low voltage mode.
B3 5 short W High Battery
B4 5 short F Over Voltage Start-up – Do not start. Run-time – Ramp down, resume if cleared.
T1 1 long W High Temp Run-time – reduce power gradually depending on temperature.
T2 1 long F Over Temp Start-up – Do not start. Run-time – Ramp down, stop.
T3 1 long W TX High Temp
T4 1 long W TY High Temp
P1 Continuous F High Pot Lock Start -up – Flash error message until POT is set to minimum.
P2 3 short F Pot Fault Start-up – Flash error message and switch off. Run-time – Ramp down, stop.
P3 3 short F Pot Fault Start-up – Flash error message and switch off. Run-time – Ramp down, resume if cleared.
P4 3 short F RC Fault Start-up – Flash error message until signal is in range. Run-time – Ramp down. Restart automatically if ranges return to normal.
P5 3 short F Limit switch Start-up – Flash error message until one or both buttons released. Run-time – Ramp down, resume if cleared.
P6 3 short F Joystick fault Start-up – Flash error message until voltage is in range.
Run-time – Ramp down, resume if cleared.
X1 1 short F Dead Mans Hdl Start-up – Flash error message until set off
Run-time – Ramp down, restart automatically if DMH goes off.
X2 1 short F Emergency Stop Start-up – Flash error message until set off.
Run-time – STOP IMMEDIATELY.
C1 None W Over Current Flash warning message. Special behaviour, emergency stop after 300 milliseconds at this level.
C2 None W Current Limit
K1 2 long F Park Brake Start-up – Do not start.
Run-time – Ramp down, stop.
Q1-4 3 long F MOSFET
S1 None W Speed Limit
S2 4 short W/F Speed Signal Flash warning message / shutdown [defaults to a warning].